    题名: A new method to estimate the amplitude spectrum analysis of ventricular fibrillation during cardiopulmonary resuscitation
    作者: 林澂;Lo, Men-Tzung;Lin, Lian-Yu;Hsieh, Wan-Hsin;Ko, Patrick Chow-In;Liu, Yen-Bin;Lin, Chen;Chang, Yi-Chung;Wang, Cheng-Yen;Young, Vincent Hsu-Wen;Chiang, Wen-Chu;Lin, Jiunn-Lee;Chen, Wen-Jone;Ma, Matthew Huei-Ming
    贡献者: 生醫理工學院生醫科學與工程學系
    关键词: Algorithms;Amplitude spectrum analysis;Automated external defibrillator;Cardiopulmonary Resuscitation - methods;Electrocardiography;Emergency;Empirical mode decomposition;Humans;Least mean square;Ventricular fibrillation;Ventricular Fibrillation - physiopathology
    日期: 2013-11-01
    上传时间: 2026-04-23 11:14:49 (UTC+8)
    出版者: Ireland: Elsevier Ireland Ltd
    摘要: 摘要: Accurate ventricular fibrillation (VF) waveform analysis usually requires rescuers to discontinue cardiopulmonary resuscitation (CPR). However, prolonged “hands-off” time has a deleterious impact on the outcome. We developed a new filter technique that could clean the CPR artifacts and help preserve the shockability index of VF We analyzed corrupted ECGs, which were constructed by randomly adding different scaled CPR artifacts to the VF waveforms. A newly developed algorithm was used to identify the CPR fluctuations. The algorithm contained two steps. First, decomposing the raw data by empirical mode decomposition (EMD) into several intrinsic mode fluctuations (IMFs) and combining the dominant IMFs to reconstruct a new signal. Second, calculating each CPR cycle frequency from the new signal and fitting the new signal to the original corrupted ECG by least square mean (LSM) method to derive the CPR artifacts. The estimated VF waveform was derived by subtraction of the CPR artifacts from the corrupted ECG. We then performed amplitude spectrum analysis (AMSA) for original VF, corrupted ECG and estimated VF. A total of 150 OHCA subjects with initial VF rhythm were included for analysis. Ten CPR artifacts signals were used to construct corrupted ECG. Even though the correlations of AMSA between the corrupted ECG vs. the original VF and the estimated VF vs. the original VF are all high (all p<0.001), the values of AMSA were obviously biased in corrupted ECG with wide limits of agreement in Bland–Altman mean-difference plot. ROC analysis of the AMSA in the prediction of defibrillation success showed that the new algorithm could preserve the cut-off AMSA value for CPR artifacts with power ratio to VF from 0 to 6dB. The new algorithm could efficiently filter the CPR-related artifacts of the VF ECG and preserve the shockability index of the original VF waveform.
    其他題名: Resuscitation
    出版者: Ireland: Elsevier Ireland Ltd
    出版日期: 2013-11-01
    出處: Resuscitation, 2013-11, Vol.84 (11), p.1505-1511
    版權: 2013 Elsevier Ireland Ltd
    版權: Elsevier Ireland Ltd
    版權: Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
    識別號: ISSN: 0300-9572
    識別號: ISSN: 1873-1570
    識別號: EISSN: 1873-1570
    識別號: DOI: 10.1016/j.resuscitation.2013.07.004
    識別號: PMID: 23851191
    显示于类别:[生醫科學與工程學系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML46检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明