English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 94459/94459 (100%)
造訪人次 : 87652502      線上人數 : 309
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/108918


    題名: Improvement in the clinical practicability of roentgen stereophotogrammetric analysis (RSA): Free from the use of the dual X-ray equipment
    作者: 賴景義;Shih, Kao-Shang;Lee, Chian-Her;Syu, Ci-Bin;Lai, Jiing-Yih;Chen, Kuo-Jen;Lin, Shang-Chih
    貢獻者: 工學院機械工程學系
    關鍵詞: Accuracy;Arthrography - instrumentation;Calibration;Equipment Design;Equipment Failure Analysis;Flat panel displays;Humans;Joint replacement surgery;Knee;Knee Joint - diagnostic imaging;Knees;Orthopedics;Platforms;Posture;Prostheses;Prosthetics;Radiographic Image Enhancement - instrumentation;Radiography, Dual-Energy Scanned Projection - instrumentation;Radiostereometric Analysis - instrumentation;Reproducibility of Results;Sensitivity and Specificity;Surgical implants;X-Ray Intensifying Screens;X-rays
    日期: 2012-10-01
    上傳時間: 2026-04-23 15:14:52 (UTC+8)
    出版者: SAGE Publications Ltd;London, England: SAGE Publications
    摘要: 摘要: After total knee replacement, the monitoring of the prosthetic performance is often done by roentgenographic examination. However, the two-dimensional (2D) roentgen images only provide information about the projection onto the anteroposterior (AP) and mediolateral (ML) planes. Historically, the model-based roentgen stereophotogrammetric analysis (RSA) technique has been developed to predict the spatial relationship between prostheses by iteratively comparing the projective data for the prosthetic models and the roentgen images. During examination, the prosthetic poses should be stationary. This should be ensured, either by the use of dual synchronized X-ray equipment or by the use of a specific posture. In practice, these methods are uncommon or technically inconvenient during follow-up examination. This study aims to develop a rotation platform to improve the clinical applicability of the model-based RSA technique. The rotation platform allows the patient to assume a weight-bearing posture, while being steadily rotated so that both AP and ML knee images can be obtained. This study uses X-ray equipment with a single source and flat panel detectors (FPDs). Four tests are conducted to evaluate the quality of the FPD images, steadiness of the rotation platform, and accuracy of the RSA results. The results show that the distortion-induced error of the FPD image is quite minor, and the prosthetic size can be cautiously calibrated by means of the scale ball(s). The rotation platform should be placed closer to the FPD and orthogonal to the projection axis of the X-ray source. Image overlap of the prostheses can be avoided by adjusting both X-ray source and knee posture. The device-induced problems associated with the rotation platform include the steadiness of the platform operation and the balance of the rotated subject. Sawbone tests demonstrate that the outline error, due to the platform, is of the order of the image resolution (= 0.145 mm). In conclusion, the rotation platform with steady rotation, a knee support, and a handle can serve as an alternative method to take prosthetic images, without the loss in accuracy associated with the RSA method.
    其他題名: Proc Inst Mech Eng H
    出版者: London, England: SAGE Publications
    出版日期: 2012-10
    出處: Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine, 2012-10, Vol.226 (10), p.766-775
    版權: IMechE 2012
    版權: Copyright SAGE PUBLICATIONS, INC. Oct 2012
    識別號: ISSN: 0954-4119
    識別號: EISSN: 2041-6518
    識別號: EISSN: 2041-3033
    識別號: DOI: 10.1177/0954411912458997
    識別號: PMID: 23157078
    顯示於類別:[機械工程學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML22檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明