中大學術數位典藏-NCU Institutional Repository:Item 987654321/108979
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 94459/94459 (100%)
造访人次 : 87652179      在线人数 : 223
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/108979


    题名: Novel application of a Wii remote to measure spasticity with the pendulum test: Proof of concept
    作者: 王淵弘;Yeh, Chien-Hung;Hung, Chi-Yao;Wang, Yung-Hung;Hsu, Wei-Tai;Chang, Yi-Chung;Yeh, Jia-Rong;Lee, Po-Lei;Hu, Kun;Kang, Jiunn-Horng;Lo, Men-Tzung
    贡献者: 工學院機械工程學系
    关键词: Adult;Aged;Arthrometry, Articular - instrumentation;Case-Control Studies;Female;Hemiplegia - physiopathology;Humans;Knee Joint - physiopathology;Male;Middle Aged;Muscle Spasticity - diagnosis;Muscle Spasticity - etiology;Muscle Spasticity - physiopathology;Orthopedics;Pendulum test;Reproducibility of Results;Severity of Illness Index;Spasticity;Stroke;Stroke - physiopathology;Video Games;Wii remote
    日期: 2016-01-01
    上传时间: 2026-04-23 15:18:51 (UTC+8)
    出版者: Elsevier;England: Elsevier B.V
    摘要: 摘要: •Fair to strong correlation of measurements between Wii and electrogoniometer.•Small and steady differences between the Wii and the electrogoniometer.•Both Wii and electro-goniometer can identify spastic limbs (p<.0001*).•High reliability in quantifying spasticity using critical spastic measure. The pendulum test is a standard clinical test for quantifying the severity of spasticity. In the test, an electrogoniometer is typically used to measure the knee angular motion. The device is costly and difficult to set up such that the pendulum test is normally time consuming. The goal of this study is to determine whether a Nintendo Wii remote can replace the electrogroniometer for reliable assessment of the angular motion of the knee in the pendulum test. The pendulum test was performed in three control participants and 13 hemiplegic stroke patients using both a Wii remote and an electrogoniometer. The correlation coefficient and the Bland–Altman difference plot were used to compare the results obtained from the two devices. The Wilcoxon signed-rank test was used to compare the difference between hemiplegia-affected and nonaffected sides in the hemiplegic stroke patients. There was a fair to strong correlation between measurements from the Wii remote and the electrogoniometer (0.513<R2<0.800). Small but consistent differences between the Wii remote and electrogoniometer were identified from the Bland–Altman difference plot. Within the hemiplegic stroke patients, both devices successfully distinguished the hemiplegia-affected (spastic) side from the nonaffected (nonspastic) side (both with p<.0001*). In addition, the intraclass correlation coefficient, standard error of measurement, and minimum detectable differences were highly consistent for both devices. Our findings suggest that the Wii remote may serve as a convenient and cost-efficient tool for the assessment of spasticity.
    其他題名: Gait Posture
    出版者: England: Elsevier B.V
    出版日期: 2016-01-01
    出處: Gait & posture, 2016-01, Vol.43 (NA), p.70-75
    版權: 2015 Elsevier B.V.
    版權: Elsevier B.V.
    版權: Copyright © 2015 Elsevier B.V. All rights reserved.
    識別號: ISSN: 0966-6362
    識別號: ISSN: 1879-2219
    識別號: EISSN: 1879-2219
    識別號: DOI: 10.1016/j.gaitpost.2015.10.025
    識別號: PMID: 26669955
    显示于类别:[機械工程學系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML37检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明