English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 96218/96218 (100%)
造訪人次 : 92462897      線上人數 : 246
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: https://ir.lib.ncu.edu.tw/handle/987654321/110882


    題名: 優化新型口腔負壓治療阻塞性睡眠呼吸中止症之療效;優化新型口腔負壓治療阻塞性睡眠呼吸中止症之療效
    作者: 粘春東;NIEN, CHUN-TUNG
    貢獻者: 生醫科學與工程學系跨領域轉譯醫學博士班
    關鍵詞: 塞性睡眠呼吸中止症;口腔負壓治療;壓力滴定;睡眠多項生理檢查;深層睡眠;Obstructive sleep apnea;Intra-oral Negative Pressure Therapy;Personalized Titration;Sleep Fragmentation;Precision Sleep Medicine
    日期: 2026-08-18
    上傳時間: 2026-10-20 16:34:45 (UTC+8)
    出版者: 國立中央大學
    摘要: 中文摘要


    一、 研究背景與動機
    阻塞性睡眠呼吸中止症(OSA)是全球盛行率逐年攀升的慢性睡眠呼吸障礙,患者因睡眠時咽喉部上呼吸道反覆塌陷與閉塞,引發間歇性低氧血症、高碳酸血症及睡眠碎片化,是導致高血壓、心肌梗塞等心血管疾病的獨立危險因子。目前臨床一線黃金標準為連續正壓呼吸器(CPAP),其利用正壓氣流作為「氣動支架」撐開氣道。然而,CPAP 在真實世界的臨床失败或中斷率高達40%至50%,主因在於強迫性正壓氣流帶來的物理不適(如黏膜乾燥、呼氣阻力)、面罩漏氣引起的微覺醒,以及面部強力束縛產生的幽閉恐懼與心理負荷。
    為克服上述弊端,新興的口腔負壓治療(OPT)系統(如 iNAP® Lite)應運而生。其透過在閉合的口腔內建立微真空環境,產生表面黏附力與力學拉力,主動將鬆弛的軟顎與後墜的舌體向前向上固定,確保咽喉通道暢通。OPT 不遮蓋口鼻、無強迫氣流,具備高依從性潛力。然而,過去早期臨床多採用固定壓力(-40 mmHg)的一體適用經驗性治療,導致療效因個體間的「解剖與病理表型異質性」(如BMI、頸圍、軟組織順應性不同)而表現出較大不穩定性,整體成功率僅約60%。
    本研究推動動機正奠基於此反思:如同 CPAP 需透過全夜睡眠多項生理檢查(PSG)進行壓力滴定才能找到最佳治療壓力,作用於複雜口腔解剖結構的 OPT,同樣必須經歷個人化的壓力滴定程序,以邁向精準睡眠醫學。

    二、 研究目的
    本研究之總體目標在於評估並論證 OSA 患者接受個人化、漸進式口腔負壓(OPT)動態滴定後的具體臨床療效。具體子目標包括:驗證其對呼吸暫停事件的初級清除療效(AHI改善與血氧穩定度);解碼微觀睡眠結構之調整(特別是 N3 深層睡眠之比例)與逆轉睡眠碎片化之機制;評估 14 天居家去敏感適應期之臨床信度與日間嗜睡改善;以及探討局部高負壓干擾之生理中性與臨床安全性邊界(如對週期性肢體抽動指數 PLM Index 的影響與局部黏膜刺激)。

    三、 研究方法
    本研究共納入 30 名 20 至 70 歲之中重度 OSA 受試者(排除中樞型呼吸中止、嚴重肺病及嚴重牙周病者)。
    第一階段(臨床篩選與基準值評估): 記錄受試者基本解剖特徵,並填寫愛普沃斯嗜睡量表(ESS)評估基線日間過度嗜睡程度。
    第二階段(14天居家適應期): 受試者正式滴定前需於家中持續使用 OPT 設備至少 14 天,建立神經習慣化去敏感,降低不適感引發的微覺醒,提升數據
    信度。
    第三階段(過夜壓力滴定實驗): 在醫院睡眠中心由專業技師監控執行。受試者同時配戴 PSG 與 OPT 裝置。初始負壓設定為 -40 mmHg,以每 15 分鐘為一評估窗口。若發生大於 2 次呼吸中止、大於 3 次低通氣、大於 5 次 RERA 或持續 3 分鐘鼾聲,則遞增 10 mmHg 負壓,壓力上限設定為生理安全閾值 -250 mmHg。最佳壓力判定指受試者處於仰臥位且進入快速動眼期(REM)時,能使呼吸事件降至最低、且血氧飽和度最穩定的最小負壓值。

    四、 研究結果與發現
    30 名受試者之平均年齡為 51.27±13.97 歲,平均 BMI 為 25.87±3.42 kg/m2。經過個人化壓力滴定介入後,核心生理指標變化如下:
    初級療效(呼吸事件與血氧改善): 全體受試者之平均 AHI 從基準值的 39.59 events/hr 大幅降至治療後的 8.17 events/hr,總體 AHI 改善率高達 80.4%,具備極其顯著的統計學差異(p < 0.001)。以治療後 AHI < 5 events/hr 為優異療效標準(Excellent response),共有 25 名受試者成功達標,總體臨床成功率高達 83.3%。夜間最低血氧飽和度(Min SpO2)也由 80.93% 顯著改善至 83.70%(p = 0.023)。
    次級療效(睡眠結構與日間症狀優化): 受試者的第三期非快速動眼睡眠(N3 深層睡眠)比例顯著由 14.89% 提升至 23.23%(p = 0.003),顯示睡眠品質得到實質質性轉變。同時,全夜微覺醒指數(Arousal Index)由 48.47 次/小時顯著降至 26.23 次/小時(p < 0.001),有效逆轉微觀睡眠碎片化。客觀指標的改善成功轉譯為日間生活品質的提升,愛普沃斯嗜睡量表(ESS)評分由 10.61 顯著降至 5.52(p < 0.001)。
    安全性與生理中性: 治療前後之週期性肢體抽動指數(PLM Index)並無統計學上的顯著差異(p = 0.816),證實當負壓逐步遞增至生理安全閾值上限時,局部物理牽引機制具備高度的解剖區域侷限性與生理中性,排除誘發治療誘導型肢體運動障礙之風險。部分受試者在高負壓下雖有短暫口腔黏膜刺激、酸痛或唾液過多等副作用,但通常在移除設備或適應後即獲得實質改善。

    五、 結論與貢獻
    本研究成功證實了口腔負壓治療(OPT)具備顯著的「劑量效應(Dose-response relationship)」,透過增加口腔內負壓的個人化滴定程序,能有效克服因個體組織順應性不同而導致的治療失敗。在流體力學上,OPT 在個人化最佳壓力下運作時,負壓完全侷限於口腔封閉艙內,口咽與鼻咽部達成力學隔離,不會像 CPAP 般增加呼吸道的呼氣阻力與呼吸功(WOB),兼具局部精準性與生理中性。
    本研究的臨床實證成功將 OPT 從過去的經驗性嘗試正式提升為「精準睡眠醫學」的標準臨床實務,不僅為廣大無法耐受黃金標準 CPAP 的 OSA 患者開闢了一條高依從性、高舒適度且客觀有效的全新一线治療希望,亦能為下一代智慧化、自動調壓型(Auto-OPT)醫療器材的密閉迴路控制演算法研發,提供關鍵的生物力學核心參數矩陣。

    關鍵詞: 阻塞性睡眠呼吸中止症(OSA)、口腔負壓治療(OPT)、壓力滴定、睡眠多項生理檢查(PSG)、深層睡眠(N3);Optimizing treatment of the novel intra-oral negative pressure for obstructive sleep apnea

    Abstract

    1. Background and Motivation
    Obstructive Sleep Apnea (OSA) is a highly prevalent chronic sleep-disordered breathing condition characterized by the recurrent collapse and occlusion of the upper airway during sleep. This anatomical obstruction induces intermittent hypoxemia, hypercapnia, and profound sleep fragmentation, serving as an independent risk factor for major cardiovascular co-morbidities such as hypertension and myocardial infarction. While Continuous Positive Airway Pressure (CPAP) remains the first-line clinical gold standard by acting as a &quot;pneumatic splint&quot; to hold the airway open, its real-world effectiveness is heavily compromised by suboptimal patient compliance, exhibiting long-term failure or discontinuation rates between 40% and 50%. This poor adherence stems primarily from the sensory discomfort of forced airflow (e.g., mucosal dryness, increased work of breathing), mask leakages that trigger cortical arousals, and psychological burdens such as claustrophobia.
    To address these critical limitations, Intra-oral Negative Pressure Therapy (OPT) systems (such as the iNAP® Lite) have emerged as an innovative alternative. By establishing a localized, sealed micro-vacuum inside the closed oral cavity, OPT utilizes surface adhesion and mechanical traction to stabilize the soft palate anteriorly and anchor the tongue superiorly and forward. This effectively clears the pharyngeal airway while keeping the nose unmasked and free of forced airflow, offering immense potential for high long-term compliance. However, early clinical implementations of OPT heavily relied on a fixed empirical pressure (typically -40 mmHg) under a &quot;one-size-fits-all&quot; paradigm. Due to the vast &quot;anatomical and pathological phenotypic heterogeneity&quot; among OSA patients—including stark variations in body mass index (BMI), neck circumference, and upper airway tissue compliance—this fixed-pressure model resulted in unstable clinical response rates hovering around only 60%. For individuals with severe obstructions or extensive pharyngeal fat infiltration, a low fixed pressure is simply insufficient to overcome the mechanical resistance of the surrounding soft tissues, leading to treatment failure.
    The motivation of this doctoral research is directly rooted in this clinical gap: just as CPAP requires an overnight titration procedure during polysomnography (PSG) to determine the ideal therapeutic pressure, OPT—acting on highly complex oral anatomy—must also undergo a systematic, personalized pressure titration protocol to transition the technology into the realm of precision sleep medicine.

    2. Research Objectives
    The primary objective of this study is to evaluate and validate the clinical and physiological efficacy of a personalized, incremental OPT dynamic titration protocol in patients with moderate-to-severe OSA. The specific sub-objectives are: to verify its primary ventilatory efficacy in eliminating obstructive events and stabilizing blood oxygen levels; to decode the qualitative shifts in macro and micro sleep architecture (particularly the restoration of N3
    deep sleep) and elucidate the mechanisms underlying the reversal of sleep fragmentation; to assess the clinical reliability of a 14-day home-based desensitization/habituation period alongside improvements in daytime symptoms; and to investigate the physiological neutrality and clinical safety boundaries of high localized negative pressure, specifically regarding its impact on the Periodic Limb Movement (PLM) Index and local mucosal irritation.

    3. Methodology
    This study prospectively enrolled 30 adult participants aged 20 to 70 years diagnosed with moderate-to-severe OSA, excluding individuals presenting with central sleep apnea, severe pulmonary disease, or advanced periodontal conditions.
    Phase I (Clinical Screening & Baseline Assessment): Comprehensive baseline anatomical characteristics were documented, and the Epworth Sleepiness Scale (ESS) was administered to quantify the severity of baseline excessive daytime sleepiness.
    Phase II (14-Day Home Habituation): Prior to the formal overnight laboratory experiment, participants utilized the OPT device at home for at least 14 consecutive days. This phase establishes neural habituation and peripheral sensory desensitization, reducing transient device-induced micro-arousals to ensure high clinical data reliability.
    Phase III (Overnight Lab Titration Experiment): Executed in a specialized sleep center under continuous monitoring by a registered sleep technologist, participants underwent full-night PSG concurrently with the OPT system. The vacuum pressure started at a baseline of -40 mmHg, using a 15-minute evaluation window. If obstructive criteria were met—defined as >2 apneas, >3 hypopneas, >5 respiratory effort-related arousals (RERAs), or continuous snoring for 3 minutes—the negative pressure was incrementally increased by 10 mmHg, up to a maximum safety threshold of -250 mmHg. The &quot;Optimal Pressure&quot; was defined as the minimum negative pressure that minimized respiratory events and stabilized oxygen saturation while the participant was in the supine position during Rapid Eye Movement (REM) sleep.

    4. Research Results and Findings
    The 30 participants had a mean age of 51.27±13.97 years and a mean BMI of 25.87±3.42 kg/m2 . Following the personalized OPT titration protocol, the core physiological parameters demonstrated remarkable shifts:
    Primary Ventilatory Efficacy (Respiratory Events and Oxygenation): The cohort′s mean Apnea-Hypopnea Index (AHI) dropped dramatically from a baseline of 39.59 events/hr to a post-treatment titrated level of 8.17 events/hr, representing a highly statistically significant overall AHI reduction rate of 80.4% (p < 0.001). Defining an &quot;Excellent Response&quot; as a post-treatment AHI < 5 events/hr, a total of 25 participants successfully achieved this clinical benchmark, yielding an overall clinical success rate of 83.3%. Concurrently, the mean minimum oxygen saturation (Min SpO2) significantly improved from 80.93% to 83.70% (p = 0.023).
    Secondary Efficacy (Sleep Architecture and Daytime Symptoms): The proportion of stage N3 non-rapid eye movement sleep (deep slow-wave sleep) increased significantly from 14.89% to 23.23% (p = 0.003), demonstrating a substantial structural optimization of sleep quality. Furthermore, the overnight Arousal Index fell significantly from 48.47 events/hr to 26.23 events/hr (p < 0.001), successfully reversing micro-sleep fragmentation. This robust objective improvement directly translated into an enhanced daytime quality of life, as evidenced by a substantial decrease in ESS scores from 10.61 to 5.52 (p < 0.001).
    Safety and Physiological Neutrality: No statistically significant difference was observed between the pre- and post-treatment Periodic Limb Movement (PLM) Index (p = 0.816). This confirms that even when the negative pressure is titrated up to the upper physiological safety limit (-250 mmHg), the mechanical traction remains highly localized to the specific upper airway structures and retains excellent physiological neutrality, eliminating the risk of treatment-induced movement disorders. Minor side effects, such as transient mucosal irritation, local soreness, or initial hypersalivation under high negative pressures, were recorded in a small subset of patients but resolved completely upon device removal or continued adaptation.

    5. Conclusions and Contributions
    This doctoral thesis successfully demonstrates a distinct &quot;dose-response relationship&quot; inherent to Intra-oral Negative Pressure Therapy; executing a personalized titration protocol capable of scaling negative pressures allows clinicians to effectively overcome the therapeutic failures previously caused by individual variations in tissue compliance. Biomechanically, when operating at an individualized optimal pressure, the negative pressure is completely contained within the sealed oral cavity. By pneumatically isolating the oropharynx from the nasopharynx, OPT avoids introducing any external expiratory resistance or adding to the patient′s work of breathing (WOB)—a massive physiological advantage over positive-pressure systems.
    Ultimately, this empirical research bridges a major translational gap, transitioning OPT from an empirical alternative into a standardized, evidence-based clinical modality within precision sleep medicine. It establishes an objective, high-compliance, and comfortable frontline clinical pathway for CPAP-intolerant patients, while providing the foundational biomechanical parameter matrices necessary for developing next-generation intelligent, closed-loop auto-adjusting (Auto-OPT) medical devices.


    Keywords: Obstructive Sleep Apnea, Intra-oral Negative Pressure Therapy, Personalized Titration, Sleep Fragmentation, Precision Sleep Medicine.
    顯示於類別:[跨領域轉譯醫學研究所] 博碩士論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML9檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明