中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/2890
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 80990/80990 (100%)
造訪人次 : 42735015      線上人數 : 1496
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/2890


    題名: 應用輪廓與灰階特徵於二維C-arm影像及三維電腦斷層影像之方位校準;Registration of 2D C-arm images and 3D CT images using contour and intensity information.
    作者: 朱鴻宇;Hung-Yu Chu
    貢獻者: 機械工程研究所
    關鍵詞: 2D-3D方位校準;影像相似性量測;最小侵入式手術;2D-3D Registration;Minimal invasive surgery;Image similarity Measure
    日期: 2008-01-09
    上傳時間: 2009-09-21 11:59:29 (UTC+8)
    出版者: 國立中央大學圖書館
    摘要: 現今的手術導引系統多半皆使用單一的影像如電腦斷層影像(CT)、核磁共振影像(MRI)或C-arm X光影像,對於微創手術(Minimal Invasive Surgery)言,若能以術前的電腦斷層影像或核磁共振影像作三維的手術規劃,再以術中的二維C-am影像進行手術定位,則微創手術將更精準與可靠。本研究發展一套能夠整合C-arm影像及三維電腦斷層影像的方位校準方法,此方法不同於一般使用CT影像的手術導引系統,只需於術中拍攝兩張C-arm影像,即可完成病患與CT影像間的方位校準,以應用在微創手術。 首先將C-arm影像扭正並計算其發射源,然後選取C-arm影像與CT影像的相同特徵點,利用特徵點的座標完成病患座標系與CT模型座標系的初始方位校準,之後以濺射成像法(Splat Rendering)產生模擬C-arm影像的數位重建X-ray影像(Digital Reconstructed Radiograph, DRR),再以最佳化方法搜尋最佳的方位校準矩陣,使DRR影像與C-arm影像達到最大相似度。本研究以灰階基礎的影像相似度量測(Intensity Based Similarity Measure)結合特徵基礎影像相似度量測(Feature Based Similarity Measure)中的輪廓方法進行影像比對量測,並使用基因演算法(Genetic Algorithm)疊代運算完成方位校準的最佳化。實驗使用脊椎塑膠切骨模型(White Plastic Saw Bone),結果顯示DRR影像輪廓的平均定位誤差為0.26mm,平均角度誤差為0.78°;C-arm影像輪廓的平均定位誤差為0.53mm,平均角度誤差為1.45°;而在針對椎體(Vertebral Body)的特徵區域圈選實驗上,平均位移誤差及平均角度誤差分別為1.09mm與3.01度。 Most image-guided surgical navigation systems use single image modality such as computed tomography, magnetic resonance imaging, or C-arm X-ray imaging. It will enhance the precision and reliability of minimally invasive surgery if there are preoperative CT or MRI images for surgical planning and intraoperative C-arm images for surgical positioning. This research develops a 2D-3D registration method for the mapping between preoperative CT images and intraoperative C-arm images. The approach is different to that of CT image based navigation system. It only needs two intraoperative C-arm images to complete the registration and can be applied to minimally invasive surgery. First, the C-arm images are calibrated and the focus point of X-ray is determined. Then, select three identical characteristic points in C-arm images and CT images to carry out the initial registration between the patient and its CT reconstructed model. After that, splat rendering is used to generate digital reconstructed radiographs (DRRs) to simulate C-arm images. Through the similarity measure of C-arm images and DRRs, the optimum transformation matrix can be found by applying optimization algorithms. This research combines the intensity based similarity measure method and the contour information of the feature based similarity measure method. Then, genetic algorithm is adopted to optimize the similarity rate and optimize the registration. In the experiment, a white plastic saw bone model of spine is used. The average registration accuracy of location and orientation of DRR images are 0.26mm and 0.77° respectively. And the registration accuracy of location and orientation of C-arm contour information are 0.53mm and 1.45° respectively. Finally, the accuracy of location and orientation of a region of interest selection experiment stressed on vertebral body are 1.09mm and 3.01° respectively.
    顯示於類別:[機械工程研究所] 博碩士論文

    文件中的檔案:

    檔案 大小格式瀏覽次數


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明