中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/3186
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 80990/80990 (100%)
造訪人次 : 42718399      線上人數 : 1327
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/3186


    題名: 具備力量量測功能之內視鏡手術工具之研發;Development of Laparoscopy Surgical system that can measured force and displacement during a Laparoscopic
    作者: 邱繼明;Chi-Ming Chiu
    貢獻者: 機械工程研究所
    關鍵詞: 系統驗證;內視鏡;力量回饋;Force Feedback;Laparoscopy;Voice Feedback
    日期: 2009-06-16
    上傳時間: 2009-09-21 12:08:18 (UTC+8)
    出版者: 國立中央大學圖書館
    摘要: 內視鏡手術具有手術傷口小、傷口疼痛感小、病人術後恢復時間快、等優點,漸漸取代了傳統的開放是手術,儼然成為二十一世紀最受矚目的手術之一,本研究利用真實手術用的內視鏡刀具,開發出一個可以直接對活體器官進行測試的內視鏡手術工具,搭配編碼器與力量感測器,可量測活體器官力量回饋特性以及進刀的行程距離,並且透過程式設計,加入提示音,探討不同型式之聲音提示對於內視鏡手術在進刀之行程誤差以及操作時間上的幫助。 系統開發方面,首先利用真實的內視鏡手術刀具設計,開發出具備活體器官力量回饋特性量測以及進刀行程量測功能之內視鏡手術工具,然後利用Visual Basic 2005與NI-6024E訊號擷取卡做連接,設計具備力量量測功能之內視鏡手術工具操作介面以及資料庫。 系統驗證方面,本研究規劃使用者信度實驗,評估使用者在操作具備力量量測功能之內視鏡手術工具時,是否會受到時間因素的影響而在操作表現上有太大差異,由信度實驗結果可以得知,讓同一批受試者在經過第一次實驗後7天,再進行相同的測試,前後測的實驗結果數據相當接近,由此可證明本系統具備信度,不會因操作時間的改變而導致不同的結果。另外探討不同聲音提示對於操作時間以及行程誤差的影響,結果表示,有聲音提示的輔助可以降低使用者的行程誤差,但是對於操作時間沒有明顯的幫助。 Laparoscopy surgeries are being widely used due to their significant advantages over traditional open surgies. However, the surgeons have to face several difficulties never experienced in open surgeries such as poor depth perception, limited field of view.Laparoscopy surgery simulation system can provide a no danger and low medical resources consume training platform.Yet, few research can effective assess the construct validity of Laparoscopy surgery simulation system. In this study we use real surgical instrument to develop a system that can measured force, displacement and time.Using the proposed system, two sets of animal experiments were conducted in an operating room to measure force-displacement and force-time of pig liver.we also add some voice that can help user in surgical training. We use Visual Basic 2005 to develop the system which includes test platform control and acquisition operating interfaces and system control interfaces, we also use Microsoft Access to establish force feedback、time and displacement database. The study adopt force feedback experiment and voice feedback experiment in order to verify the system, the results show that voice feedback have more operation accuracy than without force feedback. It also shows that voice feedback has assist in Laparoscopy surgery training. The reproducibility of the system reality assessment was analyzed using the intraclass correlation(ICC) approach.
    顯示於類別:[機械工程研究所] 博碩士論文

    文件中的檔案:

    檔案 大小格式瀏覽次數


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明