中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/462
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 80990/80990 (100%)
Visitors : 42694452      Online Users : 1438
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    Please use this identifier to cite or link to this item: http://ir.lib.ncu.edu.tw/handle/987654321/462


    Title: 園區建築物耐震能力評估;Seismic Evaluation of Buildings in Hsinchu Science-Based Industrial Park
    Authors: 陳立偉;Li-Wei Chen
    Contributors: 土木工程研究所
    Keywords: 快速目視評估方法;詳細評估方法;Rapid Visual Screening Method;Rapid Screening Procedure;Seismic Evaluation of Existing Buildings
    Date: 2000-06-20
    Issue Date: 2009-09-18 17:05:57 (UTC+8)
    Publisher: 國立中央大學圖書館
    Abstract: 本研究針對園區的建築物部分,提供耐震能力評估的方法。以期在為數眾多的建築物之中,先以快速的篩選方式,找出耐震能力較差的建築物,經過詳細的評估,對建築物的耐震能力提供建議,以做為後續耐震補強的依據、參考。 首先使用快速目視耐震評估,利用簡單的表格勾選的方式,對大量的建築物進行最快速、最初步的耐震能力評估,並且加以排序。針對需要設立門檻值,對於在門檻值之下的建築物初步判定耐震能力可能不足,必須要進入下一階段的詳細評估。 第二階段的詳細耐震評估則是對評估為耐震能力不足的建築物進行,針對不同的結構形式,以不同的評估方法進行。在詳細評估之後若發現耐震能力不足,則建議必須進行電子計算機的分析,以整個結構物進行分析並決定耐震能力足夠與否、必須加固或是使用其他加強耐震能力的方法。 The propose of this project provides the seismic evaluation methods for the buildings in Hsinchu Science-Based Industrial Park. Firstly , using the Rapid Screening Procedure to rapidly and easily identify those buildings that might pose a risk of loss of life or injury in the event of a damaging earthquake . If a building receives a low score and is thus determined to be potentially hazardous , that building would receive a further study . The second step of the Seismic Evaluation of Existing Buildings provides a method for evaluating Existing buildings to identify those that are likely to be seismically hazardous . Aiming different structure types , using different evaluating methods . If the ability of resisting earthquake is insufficient , suggesting to do further analysis of the total building or update.
    Appears in Collections:[Graduate Institute of Civil Engineering] Electronic Thesis & Dissertation

    Files in This Item:

    File SizeFormat


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明