English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 80990/80990 (100%)
造訪人次 : 42746913      線上人數 : 2463
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/48604


    題名: 以個人數位助理為平台之短暫誘發耳聲傳射檢測儀;A PDA-based transient evoked otoacoustic emission (TEOAE) system
    作者: 劉致中;Jhih-Jhong Liou
    貢獻者: 電機工程研究所
    關鍵詞: 新生兒聽力篩檢;短暫誘發耳聲傳射;個人數位助理;DNLR;PDA;otoacoustic emissions;DNLR;newborn hearing screening;transient evoked otoacoustic emission
    日期: 2011-08-27
    上傳時間: 2012-01-05 14:58:55 (UTC+8)
    摘要: 台灣新生兒聽力篩檢計畫早在1998年就已經開始推廣,但因為檢測儀器昂貴與自費的緣故,新生兒接受聽力篩檢的比率仍然偏低。本研究的目的是建構以個人數位助理為平台之短暫誘發耳聲傳射檢測儀。本系統在耳聲傳射擷取程序中,除了以衍生非線性響應(derived nonlinear response, DNLR)來消除刺激音,還使用平均的方式來降低雜訊。在聽力判定上的標準以再現性大於70 %且五個頻帶中至少三個頻帶通過為聽力正常。為了驗證本系統的功能,針對年齡約為22-79歲的6位正常聽力(Normal-Hearing, NH)和4位聽損(Hearing-Impaired, HI)的個案進行實測,實測結果與Otodynamics (Hatfield, Herts, UK)所生產的ILO292作資料比對,發現兩者對個案的聽力判定結果皆相同,並在時頻域圖上發現相似的頻率分佈與波形,由此證明本系統運用在聽力篩檢上是可行的。 Promotion of newborn hearing screening has been proposed since 1998. However, the low hearing screening percentage of the newborn remains because of expensive device and consequent high screening cost. The purpose of this study was to develop a PDA-based transient evoked otoacoustic emission (TEOAE) system. In addition to eliminate stimuli with derived nonlinear response (DNLR) method, the system decreased noise by averaging repeated acquired otoacoustic emission signals. Reproducibility over 70 % and three out of five passed frequency bands were used as criteria to determine if the hearing screening is passed or not. TEOAEs of six normal hearing and four hearing impaired subjects (22 - 79 yrs.) were measured to verify functions of our system. The measured results of our system were then compared with the screening results from commercial device ILO292 (Otodynamics Ltd, Hatfield, Herts, UK) and showed that both systems have the same screening results and similar wave forms and frequency distribution. These results indicated that the transient evoked otoacoustic emission system developed from this study could be used for hearing screening.
    顯示於類別:[電機工程研究所] 博碩士論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML684檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明