中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/50885
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 80990/80990 (100%)
造訪人次 : 42690526      線上人數 : 1492
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/50885


    題名: Full-range analysis of ambient volatile organic compounds by a new trapping method and gas chromatography/mass spectrometry
    作者: Su,YC;Liu,WT;Liao,WC;Chiang,SW;Wang,JL
    貢獻者: 化學學系
    關鍵詞: OZONE PRECURSORS;MASS-SPECTROMETRY;AIR SAMPLES;ATMOSPHERE;POTENTIALS;POLLUTANTS;LIMITS;GC
    日期: 2011
    上傳時間: 2012-03-27 18:12:09 (UTC+8)
    出版者: 國立中央大學
    摘要: This study investigated the feasibility of analyzing a full range of ambient volatile organic compounds (VOCs) from C(3) to C(12) using gas chromatograph mass spectrometry (GC/MS) coupled with thermal desorption. Two columns were used: a PLOT column separated compounds lighter than C(6) and a DB-1 column separated C(6)-C(12) compounds. An innovative heart-cut technique based on the Deans switch was configured to combine the two column outflows at the ends of the columns before entering the MS. To prevent the resolved peaks from re-converging after combining, two techniques were attempted (hold-up vs. back-flush) to achieve the intended "delayed" elution of heavier components. Thus, the resulting chromatogram covering the full range of VOCs is a combination of two separate elutions, with the heavier section following the lighter section. With the hold-up method, band-broadening inevitably occurred for the delayed C(6)-C(7) DB-1 compounds while the light compounds eluted from the PLOT column. This broadening problem resulted in peak tailing that was largely alleviated by adding a re-focusing stage while the DB-1 compounds were back-flushed, and this modified technique is referred to as the back-flush method. With this modification, the separation of the C(6)-C(7) compounds improved dramatically, as revealed by the decrease in peak asymmetry (As) and increase in resolution. Linearity and precision for these peaks also improved, yielding R(2) and RSD values better than 0.9990 and 2.8%, respectively. (C) 2011 Elsevier B.V. All rights reserved.
    關聯: JOURNAL OF CHROMATOGRAPHY A
    顯示於類別:[化學學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML609檢視/開啟


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明