題名: | Detrended fluctuation analysis predicts successful defibrillation for out-of-hospital ventricular fibrillation cardiac arrest |
作者: | Lin,LY;Lo,MT;Ko,PCI;Lin,C;Chiang,WC;Liu,YB;Hu,K;Lin,JL;Chen,WJ;Ma,MHM |
貢獻者: | 系統生物與生物資訊研究所 |
關鍵詞: | WAVE-FORM ANALYSIS;CARDIOPULMONARY-RESUSCITATION;TIME-SERIES;VARIABILITY;AMPLITUDE;DOGS |
日期: | 2010 |
上傳時間: | 2012-03-27 18:20:27 (UTC+8) |
出版者: | 國立中央大學 |
摘要: | Aims: Repeated failed shocks for ventricular fibrillation (VF) in out-of-hospital cardiac arrest (OOHCA) can Worsen the Outcome. It is very important to rapidly distinguish between early and late VF. We hypothesised that VF waveform analysis based on detrended fluctuation analysis (DFA) can help predict successful defibrillation. Methods: Electrocardiogram (ECG) recordings of VF signals from automated external defibrillators (AEDs) were obtained for subjects with OOHCA in Taipei city. To examine the time effect on DFA, we also analysed VF signals in subjects who experienced Sudden cardiac death during Holter study from PhysioNet, a publicly accessible database. Waveform Parameters including root-mean-squared (RMS) amplitude, mean amplitude, amplitude spectrum analysis (AMSA), frequency analysis as well as fractal measurements including scaling exponent (SE) and DFA were calculated. A defibrillation was regarded as Successful when VF was converted to an organised rhythm within 5 s after each defibrillation. Results: A total of 155 OOHCA subjects (37 successful and 118 unsuccessful defibrillations) with VF were included for analysis. Among the VF waveform parameters, only AMSA (7.61 +/- 3.30 vs. 6.30 +/- 13.13, P=0.028) and DFA alpha 2 (0.38 +/- 0.24 vs. 0.49 +/- 0.24, P=0.013) showed significant difference between subjects With Successful and unsuccessful defibrillation. The area under the Curves (AUCs) for AMSA and DFA alpha 2 was 0.63 (95% confidence interval (CI) = 0.52-0.73) and 0.65 (95% CI = 0.54-0.75), respectively. Among the waveform parameters, only DFA alpha 2, SE and dominant frequency showed significant time effect. Conclusions: The VF waveform analysis based on DFA could help predict first-shock defibrillation Success in patients with OOHCA. The clinical utility of the approach deserves further investigation. (C) 2009 Elsevier Ireland Ltd. All rights reserved. |
關聯: | RESUSCITATION |
顯示於類別: | [系統生物與生物資訊研究所] 期刊論文
|
文件中的檔案:
檔案 |
描述 |
大小 | 格式 | 瀏覽次數 |
index.html | | 0Kb | HTML | 972 | 檢視/開啟 |
|
在NCUIR中所有的資料項目都受到原著作權保護.
|
::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::