中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/54567
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 80990/80990 (100%)
造访人次 : 42693344      在线人数 : 1569
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/54567


    题名: 單相太陽能市電併聯型換流器之研製;Design and Implementation of Grid-Connected Single-Phase Photovoltaic Inverter
    作者: 黃登基;Huang,Deng-chi
    贡献者: 電機工程研究所碩士在職專班
    关键词: 市電併聯型換流器;最大功率追蹤;太陽能電池;grid-connected inverter;maximum power point tracking;Photovoltaic cell
    日期: 2012-08-16
    上传时间: 2012-09-11 18:54:11 (UTC+8)
    出版者: 國立中央大學
    摘要: 本文旨在研製一單相2KW太陽能市電併聯型換流器,將太陽能板所產生的直流電力轉換成交流電力輸出,由於太陽能電池輸出電壓、電流容易受到日照強度與溫度的影響,而造成最大功率點的漂移,因此需利用最大功率追蹤及電力電子技術來汲取太陽能光電池可用之最大功率,而太陽能換流器的功率電路是由直流升壓型轉換器與全橋式換流器兩級電路所組成。本系統可直接與市電併聯供電,以紓解尖峰負載用電的問題。  市電併聯型太陽能換流器的三大設計重點為:最大功率追蹤、輸出交流電流控制與孤島效應的偵測,本文以數位信號處理器(DSP-TMS320F2808)為核心來實現系統之數位控制,而市電併聯實測電流總諧波失真低於5%,整體最大效率在96%以上,最後以PSIM模擬與實際製作2KW市電併聯型換流器之實測結果來驗證系統之性能。This thesis presents the design and implementation of the 2KW grid- connected single-phase photovoltaic inverter. The inverter converts dc power generated by photovoltaic cells into ac power. Due to that output voltage and current of the photovoltaic cells are easily changed by light and temperature fluctuations, it will casue the maximum power point drift. Therefore, maximum power point tracking and power electronic technique are required to draw the available maximum power from the photovoltaic cells. The power circuit of the photovoltaic inverter is composed of boost converter and full-bridge inverter. The output of the inverter is directly connected to utility grid system to supply peak load.   There are mainly three design goals for a grid-connected photovoltaic inverter: maximum power point tracking output current control of the inverter and islanding effect detection. A digital signal processor is applied for the system control Experimental results show that the current total harmonic distortion measured is less than 5% with maximum efficiency above 96% Finally , the performance of the proposed configuration is verified by PSIM simulation results and hardware measurements of the 2KW grid-connected inverter.
    显示于类别:[電機工程學系碩士在職專班] 博碩士論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML1741检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明