English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 78852/78852 (100%)
造访人次 : 36753602      在线人数 : 629
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/60737


    题名: 粒徑大小對奈米銀自發磁性之影響;The spontaneous magnetism of silver nanoparticles by particle size
    作者: 林元媛;Lin,Yuan-Yuan
    贡献者: 物理學系
    关键词: 粒徑大小;自發磁性;奈米銀;particle size;spontaneous magnetism;silver nanoparticle
    日期: 2013-07-22
    上传时间: 2013-08-22 11:47:15 (UTC+8)
    出版者: 國立中央大學
    摘要: 對平均?徑1.8 nm、3.5 nm、6.9 nm和9.7 nm的銀樣品,使其在各個不同的溫度下改變外加磁場,進?磁化率量測實驗,探討?徑大小對其自發磁性之影響,並用朗之萬函數進行磁化曲線擬合。本研究使用熱蒸鍍冷凝法製備奈米銀顆粒,利用X光繞射圖譜來判定粒徑大小。
    和塊材銀的微弱反磁現象不同,奈米銀由於單位體積的表面積增加而產生自旋極化,有明顯的順磁和反磁現象,在1.8 K時1.8奈米的樣品飽合磁化強度約為其它較大粒徑的樣品(從3.5奈米到9.7奈米)的6到13倍且其反磁現象也較強烈;而在300 K時1.8奈米的樣品飽合磁化強度則為其它較大樣品的4到7倍。由修正過的?之萬函?加上修正反磁項擬合所得到不同粒徑大小樣品的磁化曲線圖擬合良好。
    This paper discussed the size of silver nanoparticles influences their susceptibility. On the average particle diameter of 2.8 nm, 4.5 nm, 12 nm and 21 nm nano-silver and bulk silver, compared their different temperatures while changing the applied magnetic field, measured their conducting magnetization rate and magnetization intensity to explore the particles size of the spontaneous magnetic effects and magnetization curve fitting. This study was prepared using thermal evaporation condensation nano silver particles, using X-ray diffraction to determine the particle size.
    And nano-silver reacts differently the non-magnetized bulk silver
    its surface area per unit volume increases the spin polarization phenomena which have the results in significant paramagnetic and diamagnetic phenomena. at the saturation magnetization of 1.8 nm nanosilver samples is about 6 to 13 times of other larger samples (from 3.5 nm to 9.7 nm) at 1.8 K, and the phenomenon of their diamagnetic relatively strong
    they have similar phenomena at 300 K and 1.8 K, the saturation magnetization of 1.8 nm nanosilver sample is about 4-7 times of other larger nanosilver sample. After the correction of the .Langevin function with diamagnetic correction, the fitting graphs of different particle size nanosilver show good fit.
    显示于类别:[物理研究所] 博碩士論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML682检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明