中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/6089
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 80990/80990 (100%)
造訪人次 : 42744518      線上人數 : 1220
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/6089


    題名: 大體積固相微萃取技術應用於被動式空氣採樣及動力學探討;Large Volume Solid Phase Microextraction for passive air sampling
    作者: 詹季儒;Ji-Ru Jame
    貢獻者: 化學研究所
    關鍵詞: 被動式採樣;大體積固相微萃取;脫附;聚二甲基矽氧烷;動力學常數;kinetic constant;polydimethylsiloxane (PDMS);large volume solid phase microextraction;diffusion
    日期: 2004-06-25
    上傳時間: 2009-09-22 10:13:03 (UTC+8)
    出版者: 國立中央大學圖書館
    摘要: 本實驗利用增加靜相體積之概念,以提高分析物的萃取量,自行塗怖PDMS及PDMS/Carboxen高分子薄膜,其成分接近商業化固相微萃取(Solid phase microextraction)的吸附靜相,配合自行研發之進樣裝置,使熱脫附分析物不再侷限氣相層析儀(GC)之注射埠,大幅降低偵測極限。實驗過程中設計組裝一套熱脫附進樣系統,使用benzene、toluene、ethylbenzene、m-xylene、o-xylene (BTEX)純物質全量進樣作為校正曲線(calibration curves),驗證此系統可達良好線性範圍(R2>0.99)及再現性(1.07%)。 此外搭配自行設計頂空採樣裝置(headspace sampling device)分析濃度10 &micro;g/L (ppb) BTEX樣品6次,其再現性4~12%。以及連續熱脫附方式,分析之同濃度BTEX,結果顯示分析物在PDMS及PDMS/Carboxen高分子薄膜脫附模式皆呈現指數下降曲線[Q/q0=exp(-aN)]符合典型之擴散行為,其PDMS及PDMS/Carboxen高分子薄膜感度對熱脫附次數存在良好的相關性(R2>0.99),並探討動力學常數a值對吸附及脫附效率之影響;且利用動力學常數,求得分析物在基質中的濃度及與靜相的分配常數,以及檢量未知空氣中BTEX的濃度。 近年來由於固相微萃取的材料特性與本身的構造設計,可以濃縮萃取揮發性物質,顯示了作為空氣採樣器的可能性,本實驗使用自製的PDMS及PDMS/Carboxen高分子薄膜作為被動式採樣器;以及頂空採樣裝置作為簡化空氣中變數,自製大體積PDMS及PDMS/Carboxen裝置無論對於標準樣品或真實空氣皆可達到良好的感度及解析度,尤其以PDMS/Carboxen對真實空氣效果更佳。 This research is based upon a simple SPME (solid phase micro-extraction) theory, in which the sensitivity of SPME is proportional to the volume of the polymer phase, assuming the volume of the polymer phase is negligible compared to that of an aqueous sample. A thick film of polydimethylsiloxane (PDMS) polymer was coated on a glass rod of 2 mm O.D. x 6.7 cm length to serve as a large volume solid phase extraction medium for increasing sensitivity. A renovated thermal desorption device was retrofitted from a regular GC injector to accommodate the thick PDMS rod. To cope with peak broadening in chromatography, an in-line micro-sorbent trap packed was installed prior to the capillary column to focus volatile analytes slowly desorbed from the large volume PDMS rod, resulting in highly resolved peaks. By placing various amounts of high purity benzene, toluene, ethylbenzene, m-xylene, o-xylene (BTEX) into the thermal desorption device the linearity and precision of the injection system were effectively validated with R2 > 0.99 and RSD < 1.07%, which lays a solid ground for the subsequent quantitative and kinetic studies. Throughout the experiment a headspace device was designed to generate standard gas mixture by equilibrating headspace with a standard aqueous solution containing target compounds of BTEX. The large volume SPME was able to achieve repeatability of 4~12% for BTEX, sufficient for high quality quantitative analysis. Thermal desorption of the PDMS or PDMS/Carboxen rod showed a rapid exponential decline with the residue which can be described by the first order kinetics [Q/q0=exp(-aN)] and conformed to the diffusion theory. Herein, the kinetic constant can be described as the efficiency of sorption and desorption and has been shown to be temperature dependent but independent of extraction time and sample concentration. The simplified kinetics allows rate constants to be easily determined by arbitrarily loading and successive desorption of the target compounds at arbitrary extraction time. Using rate constants and equilibrium constants the concentrations of volatile analytes in both air and water can be easily calculated avoiding conventional time-consuming calibration procedures. Both water and air samples were tested by the large volume SPME to show the sensitivity due to volume merit and the overall applicability of this self-developed technique.
    顯示於類別:[化學研究所] 博碩士論文

    文件中的檔案:

    檔案 大小格式瀏覽次數


    在NCUIR中所有的資料項目都受到原著作權保護.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明