中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/61264
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 80990/80990 (100%)
Visitors : 42667437      Online Users : 2108
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    Please use this identifier to cite or link to this item: http://ir.lib.ncu.edu.tw/handle/987654321/61264


    Title: 電腦輔助長骨創傷手術骨板置放與模擬
    Authors: 王明暄;Wang,Ming-Hsuan
    Contributors: 機械工程學系
    Keywords: 碰撞偵測;貼附;誤差分析;長骨手術;術前規劃;醫學影像;collision detection;error analysis;preoperative planning
    Date: 2013-07-11
    Issue Date: 2013-08-22 12:16:27 (UTC+8)
    Publisher: 國立中央大學
    Abstract: 骨板置放與模擬為利用電腦於術前模擬骨板的置放位置,提供醫師術前挑選合適的骨釘骨板等植入物,避免術中的不確定性,一般的模擬放置功能操作上不但繁瑣,且無法辨別過程中骨板有無陷入。本研究之骨板放置功能,以碰撞偵測技術為基礎,開發出便捷和快速的操作方式,不但自動貼附於骨表面和顯示貼附度,且絕無陷入之情況,並搭配PhysiGuide平台發展一長骨術前評估系統。最後驗證不陷入之正確性和貼附精度,再藉由兩個股骨與五個骨盆案例,比較本研究之骨板放置與原本放置方式之操作時間,說明此功能的可行性及廣用性。
    Computer assisted implant placement and simulation provides information to aid the choice of the type and size of the implants in preoperative planning. The general implant placement and simulation is not only time consuming, but also insufficient in function. We present a method for implant placement based on a collision detection technique, and develop algorithms for appropriate attachment between the implant and the bone and the evaluation of the attachment. In particular, the proposed method guarantees no penetration between the implant and the bone, which is better than old scheme with rotation and translation algorithms. Finally, we combine the proposed method and PhysiGuide in a 3D medical imaging platform, for the preoperative planning of long bones. To verify the above scheme, two femur cases and five pelvic cases are used to evaluate the feasibility of the proposed method. The test results show that the accuracy and efficiency of the proposed implant placement method meet our design requirement.
    Appears in Collections:[Graduate Institute of Mechanical Engineering] Electronic Thesis & Dissertation

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML468View/Open


    All items in NCUIR are protected by copyright, with all rights reserved.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明