中大機構典藏-NCU Institutional Repository-提供博碩士論文、考古題、期刊論文、研究計畫等下載:Item 987654321/62665
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 80990/80990 (100%)
造访人次 : 43940183      在线人数 : 1636
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.lib.ncu.edu.tw/handle/987654321/62665


    题名: 金屬玻璃於醫療器械之研發與應用 : 材料開發與評估-新穎塊狀金屬玻璃應用於醫療器械之製備與性能探討;Development of Novel Bulk Amorphous Alloy on the Clinical Device Application and its Properties Investigation.
    作者: 鄭憲清;陳明仁;張世幸;黃文傑;林俊昌
    贡献者: 國立中央大學材料科學與工程研究所
    关键词: 材料科技
    日期: 2013-12-01
    上传时间: 2014-03-17 11:53:34 (UTC+8)
    出版者: 行政院國家科學委員會
    摘要: 研究期間:10208~10307;Bulk metallic glass (BMG) possess plenty good engineering properties such as high fracture strength, high hardness, relative high impact fracture energy, high elastic strain, and excellent corrosion resistance for Zr-based metallic glass. In parallel, Zr-based BMG is found to have the most potential for commercialization among these BMGs. In this study, we plan to select the Zr-base and ZrCu-base BMGs (Zr53Cu29.5Ni9Al8Si0.5 and Zr42Cu41.5Al8Ag8Si0.5) with high glass forming ability which was pre-studied in our previous research as the base alloy. In the 1st year, one set of arc-melting and vacuum suction-aided tilt casting system will be designed and set up to fabricate the high quality BMG plates. The microstructure, mechanical properties, and thermal properties of these BMG plates will be characterized. In addition, these BMG plates and assembled targets will be provided to the other subproject. In the 2nd year, major work emphasized to develop a self-made Zr-base and ZrCu-base BMGs blade and medical instruments and characterized its microstructure, mechanical properties and blade sharpness index (BSI). The BMG plates and assembled 3 inches target will be provided to other subprojects for investigate the antibacterial properties. In parallel, the evaluation of thermoplastic ability of the Zr-base and ZrCu-base BMGs will be conducted in this year. For the 3rd year, a Ni-free Ti-base (Ti-Cu-Al-Nb-Si) BMG will be developed and characterized. One medical micro device (cross-section < 1 mm) will be selected as the goal to study the precision thermoplastic forming process. The mechanical properties, sharpness, and wear resistance of these medical devices will be evaluated for establishing the process window of precision thermoplastic forming. In combination with the other 3 subprojects, we hope to promote the series of Zr-base and Ti-base BMG on the application of medical tool.
    關聯: 財團法人國家實驗研究院科技政策研究與資訊中心
    显示于类别:[材料科學與工程研究所 ] 研究計畫

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML459检视/开启


    在NCUIR中所有的数据项都受到原著作权保护.

    社群 sharing

    ::: Copyright National Central University. | 國立中央大學圖書館版權所有 | 收藏本站 | 設為首頁 | 最佳瀏覽畫面: 1024*768 | 建站日期:8-24-2009 :::
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 隱私權政策聲明